Applicators are air coils wound from enamelled copper or other special wire in a special construction. The surface of such applicator is in accordance with the user requirements and relevant standards.
It consists of top-quality imitation leather complying with hygienic standards for contact with the human skin.
width 54 cm, height 108 cm (with M7S applicator), depth 200 cm, weight 50 Kg, MIMF 2.5 mT
Usage: Use for in-depth application over the whole body. It supports maximum comfort for less mobile patients.
width 125 mm, height 155 mm, depth 28 mm, weight 350 g, MIMF 35 mT
Usage - Local applications, recommended for stimulation of nerve endings (feet). The type
with vibration (on request) is marked M1Sb.
width 290 mm, height 245 mm, depth 80 mm, weight 1180 g, MIMF 6 mT
Usage - For applications on joints, cervical spinal column, head. The applicator generates a spatial magnetic field – suitable for depth applications.
width 310 mm, height 320 mm, depth 170 mm, weight 2340 g, MIMF 4 mT, flat bottom (to make the application more comfortable).
Usage - A medium solenoid, suitable for depth applications. To be used on joints, feet, cervical
spinal column, head, etc.
width 470 mm , height 475 mm, depth 120 mm, weight 2860 g, MIMF 4 mT, flat bottom to make the application more comfortable.
Usage - A body solenoid, suitable for depth applications. To be used on hips, spinal column, also possible to work with the shoulders at the same time, etc., since the applicator is easy to handle.
width 520 mm, height 520 mm, depth 340 mm, weight 8600 g, MIMF 1 mT, flat bottom to make the application more comfortable.
Usage - A deep body solenoid, suitable for depth applications. To be used on extremities, hips, spinal column, also possible to work with the shoulders at the same time, etc. This type is recommended for application with people lying on a bed.
width 600 mm, height 600 mm, depth 340 mm, weight 10100 g, MIMF 1.1 mT, flat bottom to make the application more comfortable.
Usage - A body solenoid, suitable for depth applications. To be used on hips, spinal column, also possible to work with the shoulders at the same time, etc., since the applicator is easy to handle.
width 720 mm, height 730 mm, depth 300 mm, weight 14820 g, MIMF 2.5 mT
Usage - The largest body solenoid, with parameters that serve well for application on heavy bodies, or for application with the bed pulled in. This type is recommended for depth applications. To be used on hips, spinal column, also possible to work with the shoulders at the same time, etc.
width 300 mm, height 230 mm, weight 540g, MIMF 10 mT
Usage - A local applicator to be put on painful spots (throughout the body).
width 300 mm, height 500 mm, weight 1035 g, MIMF 8 mT
Usage - A two-part flexible applicator to be put on painful spots (throughout the body).
width 380 mm, height 720 mm, depth 28 mm, weight 1435 g, MIMF 5 mT
Usage: flexible three-part applicator, which is suitable for larger applications (spinal column, extremities and so no.)
Width 460 mm, height 970 mm, depth 28 mm, weight 1865 g, MIMF 14 mT
Usage: four-part flexible applicator, which is suitable for larger applications (spinal column, extremities and so no.)
width 600 mm, height 105 mm, anatomic shape, weight 680 g, MIMF 12 mT
Usage - Flexible, anatomic applicator, suitable for application with cervical spinal column and shoulders at the same time.
width 880 mm, height 500 mm, weight 1925 g, MIMF 4 mT
Usage - For applications especially in case of general rehabilitation, patient seated or lying on the bed; if connected with applicator M12 Ab, a whole-bed applicator is created.
width 880 mm, height 500 mm, weight 1825 g, MIMF 5 mT
Usage - For applications especially in case of general rehabilitation, patient seated or lying on the bed; if connected with applicator M12 Aa, a whole-bed applicator is created.
The upper (marked) part is intended for the patient’s head, as it does not generate the
pulse magnetic field.
width 440 mm, height 400 mm, weight 935 g, MIMF 6 mT
Usage - A three-part flexible applicator, suitable for application onto the back (also extremities, etc.). The LPMF is in the edge parts as well. For fixation, use tape (a zipper cannot be used).
width 350 mm, height 500 mm, weight 1020 g, MIMF 12 mT
Usage - A two-part flexible applicator to be put on painful spots (e.g. back, also throughout the body). In connection with part M14 Ab, a size of 100 cm is created, designed for application on the entire surface of the back; application on both hips at once is possible as well.
width 350 mm, height 500 mm, weight 1020 g, MIMF 12 mT
Usage - A two-part flexible applicator to be put on painful spots (e.g. back, also throughout the body). In connection with part M14 Aa, size 100 cm is created, designed for application on the entire surface of the back; application on both hips at once is possible as well.
width 250 mm, height 210 mm, weight 380 g, MIMF 20 mT
Usage - An applicator for specific local applications, designed for connection to the M11A type. This version may be used as a stomatological applicator as well.
width 250 mm, height 210 mm, weight 380 g, MIMF 20 mT
Usage - A mirror version of applicator M15Aa, the same method of application.
An orthopaedic aid intended for fixation of the applicator, provided with a 20 cm zipper.
A head pad, for applicators with a 20 cm zipper.
Flat applicators excite the magnetic field of the highest intensity, however, spatially inhomogeneous. The magnetic field intensity depends on the distance from the surface of the applicator (e.g. at distance of 8 cm the intensity drops to a mere 20 % of the surface value). They are used in cases we do not require the magnetic field to penetrate to the tissues deep under the surface. The most powerful magnetic field is in the axis near the surface. The distribution of the pulse magnetic field intensity may be verified by Biomag® Tester (included in the supply). The maximum value of the magnetic field provided in the specifications was measured at the surface of the applicator, in the middle of the magnetic segments.
Cylinder or ring applicators generate a homogenous magnetic field, however, rather less intensive than the one generated by the flat applicators. They are used even if the effects of the magnetic field are emphasised and in case we need the field to penetrate deep into the tissues (e.g. if applied on extremity joints). You may verify the range of the spatial pulse magnetic field with the Biomag® Tester as well. The maximum value of the magnetic field provided in the specifications was measured at the inner surface of the applicator, at the
edge of the cylindrical section.
The Biomag Mona device is able to generate magnetic field pulses with top quality parameters. Therefore, in case of some applicators the therapeutic effects of the magnetic field are reached within a range of 3 to 5 mT.
The most powerful magnetic field (35 mT) is provided by the M1S applicator.
Applicators with a higher magnetic field intensity are used for local applications (point applications); applicators with a lower intensity are used for other applications. The most important thing is to let the pulse magnetic field act directly upon the afflicted spot on the body (sometimes two applicators at a time are used, i.e. the concept of “cause and effect” is applied).
MAGNETIC FIELD POLARITY
The north polarity of the pulses shows rather analgesic effects, so it serves well for e.g. migraine, toothache, etc.
The south polarity shows more stimulating effects, so it works well for e.g. periodontal disease, dermatological diseases, etc.
Biomag® Tester (a part of the supply)
Using the Biomag® Tester you can determine the polarity of the applicator or its point. The north pole is marked (-), while the south pole is marked (+).
How to measure the polarity on the applicator: If you bring the Biomag® Tester to the surface of the applicator activated, the Tester starts vibrating, following the rhythm of the pulse frequency. You can find out the polarity of the applicator placing the Tester with the (-) mark against the surface of the applicator in operation. If the Biomag® Tester is repelled (pushed away), you are working with the north pole of the applicator, while if it is drawn towards the surface, this is the south pole of the applicator.
Indication of applicator polarity. The north polarity of the applicator is marked on the plate with a green circle and the letter N. If the plate is between the components, the circle with the letter N shows an arrow directed
to the nearest component with northern polarity (e. g. N^).
If an applicator consists of more parts, the polarity comes in turns so that the magnetic lines of force do not interfere with each other but are amplified when the applicator is bent. As for the solenoids, the polarity of the magnetic field may be determined with the Biomag® Tester on the opposite sides of the section (edge) of the ring.
While making the decision which applicator should be used, especially as regards solenoids, the applicator polarity is not very important (the individual sensitivity of the patient may be considered, though).